Cini

Property Test method Min requirements Ulva test result
& report number
Temperature range   0 - 90°C Pass
E4707
Weight   2 kg/m2 Pass
E4707
Bending strength ISO 178 130 Mpa Pass
E4707
Tensile strength ISO 527 50 Mpa Pass
E4707
Elongation at break   1% Pass
E4707
Compression strength ISO 604 125 Mpa Pass
E4707
Impact resistance ISO 179 57 KJ/m2 Pass
D10508
Temper Barcol 45 Pass
D10508
Layer thickness   1.5mm Pass
E4707
Water vapour permeability M2.h.mmHg 0.001g *
E4707
Flame spread index ASTM E84 20 Pass
101900785SAT-001A

* Water vapour permiability is dependent upon thickness.

Cini 3.2.11 states:

(1) Water vapour permeability in acc. with ASTM E96, procedure E.If exceeding the indicated value, for application as primary vapour barrier in cold insulation systems only in combination with vapour barrier multiplex foil (CINI 3.3.05 ).